A Comparison of Patients Absorption Doses with Bone Deformity Due to the EOS Imaging and Digital Radiology | ||
The Archives of Bone and Joint Surgery | ||
مقاله 4، دوره 5، شماره 3، مرداد 2017، صفحه 145-148 اصل مقاله (345.97 K) | ||
نوع مقاله: RESEARCH PAPER | ||
شناسه دیجیتال (DOI): 10.22038/abjs.2017.21918.1568 | ||
نویسندگان | ||
Seyed Mohammad J. Abrisham1؛ Fathollah Bouzarjomehri2؛ Reza Nafisi-Moghadam3؛ Mohammad R. Sobhan* 1؛ Mahdie Gadimi4؛ Fereshte Omidvar4 | ||
1Department of Orthopedics, Shahid Sadoughi University of Medical Sciences, Yazd, Iran | ||
2Medical Radiation group, Islamic Azad University, Central Tehran branch, Tehran, Iran | ||
3Department of Radiology, Shahid Sadoughi University of Medical Sciences, Yazd, Iran | ||
4Department of Medical Physics, Shahid Sadoughi University of Medical Sciences, Yazd, Iran | ||
چکیده | ||
Background: This study has aimed to measure the patient dose in entire spine radiography by EOS system in comparison with the digital radiography. Methods: EOS stereo-radiography was used for frontal and lateral view spine imaging in 41 patients in a prospective analytical study. A calibrated dose area product (DAP) meter was used for calibration of the DAP in EOS system. The accuracy and precision of the system was confirmed according to the acceptance testing. The same procedure was used for 18 patients referred for lumbar spine digital radiology (overall 36 images). Results: Although radiation fields in the EOS were almost twice of that in digital radiology, and the average peak tube voltage (kVp), current supply to the tube (mA), and the average size and age of the patients referred for EOS imaging were greater than digital radiology, however, the average DAP in EOS was 1/5 of that in digital radiology system. Also, the average dose in the EOS was about 1/20 of that in digital radiology. Conclusion: The patient dose in EOS imaging system was lower in comparison with digital radiology (1/20). | ||
کلیدواژهها | ||
Digital Radiography؛ Dose Area Product؛ Dosimetry؛ EOS؛ Stereo Radiography | ||
مراجع | ||
1. Kim HY, Lee SK, Lee NK, Choy WS. An anatomical measurement of medial femoral torsion. J Pediatr Orthop B. 2012; 21(6):552-7. 2. Rehani MM, Berry M. Radiation doses in computed tomography. The increasing doses of radiation need to be controlled. BMJ. 2000; 320(7235):593-4. 3. Buck FM, Guggenberger R, Koch PP, Pfirrmann CW. Femoral and tibial torsion measurements with 3D models based on low-dose biplanar radiographs in comparison with standard CT measurements. AJR Am J Roentgenol. 2012; 199(5):W607-12. 4. National Institute for Health and Clinical Excellence (NICE) Diagnostics Assessment Programme: EOS ultra-low dose 2D/3D x-ray imaging system for postural assessment. Request for information on topic. London: NICE; 2010. P. 5. 5. National Institute for Health and Clinical Excellence (NICE) EOS 2D/3D x-ray imaging system: final scope. London: NICE, Diagnostics Assessment Programmed; 2010. 6. Faria R, McKenna C, Wade R, Yang H, Woolacott N, Sculpher M. The EOS 2D/3D X-ray imaging system: a cost-effectiveness analysis quantifying the health benefits from reduced radiation exposure. Eur J Radiol. 2013; 82(8):e342-9. 7. Escott BG, Ravi B, Weathermon AC, Acharya J, Gordon CL, Babyn PS, et al. EOS low-dose radiography: a reliable and accurate upright assessment of lower-limb lengths. J Bone Joint Surg Am. 2013; 95(23):e1831-7. 8. Baunin C. Comparison between EOS imaging and CTscan for the femoral and tibial torsion measurements in children. Congress of European Society of Radiology, Vienna, Austria; 2014. 9. Mahboub-Ahari A, Hajebrahimi S, Yusefi M, Velayati A. EOS imaging versus current radiography: a health technology assessment study. Med J Islam Repub Iran. 2016; 30(1):331. 10. McKenna C, Wade R, Faria R, Yang H, Stirk L, Gummerson N, et al. EOS 2D/3D X-ray imaging system: a systematic review and economic evaluation. Health Technol Assess. 2012; 16(14):1-188. 11. Dubousset J, Charpak G, Skalli W, Deguise J, Kalifa G. EOS: A new imaging system with low dose radiation in standing position for spine and bone and joint disorders. J Musculoskelet Res. 2010; 13(1):1-12. 12. Pardellanse JP. [PhD Thesis]. Assessments of a microgrid Ionization chamber (EOS) for Low Dose Chest Radiography. Barcelona, Spain: Medicine Department of University of Barcelona; 2015. | ||