The Effect of Sagittal Femoral Bowing on the Femoral Component Position in Total Knee Arthroplasty | ||
| The Archives of Bone and Joint Surgery | ||
| مقاله 9، دوره 5، شماره 4، مهر 2017، صفحه 251-255 اصل مقاله (405.95 K) | ||
| نوع مقاله: RESEARCH PAPER | ||
| شناسه دیجیتال (DOI): 10.22038/abjs.2017.8431 | ||
| نویسندگان | ||
| Seyyed Morteza Kazemi؛ Tooraj Shafaghi؛ Reza Minaei* ؛ Reza Osanloo؛ Hashem Abrishamkarzadeh؛ Farshad Safdari | ||
| Bone Joint and Related Tissues Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran | ||
| چکیده | ||
| Background: In the current study, we investigated that how sagittal femoral bowing can affect the sagittal alignment of the femoral component in total knee arthroplasty (TKA). Methods: There were 25 patients underwent TKA. Long leg radiography in lateral view was performed. The sagittal femoral bowing (SFB) and component alignment in relation to the sagittal mechanical axis and distal anterior cortical line (DACL) were measured. Finally, the correlation of component alignment and SFB was examined. Results: Mean SFB was 7±2.7 degrees. The component was in flexion position in relation to mechanical axis and DACL as 8.4±2.9 degrees and 1.7±0.9 degrees, respectively. The flexion alignment of the component was significantly correlated with SFB. Conclusion: Mechanical alignment of the limb in both coronal and sagittal axes should be preserved in TKA. SFB can significantly increased the flexion alignment of the femoral component. | ||
| کلیدواژهها | ||
| alignment؛ sagittal femoral bowing؛ Total knee arthroplasty | ||
| مراجع | ||
|
1. Cherian JJ, Banerjee S, Kapadia BH, Jauregui JJ, Harwin SF, Mont MA. Cementless total knee arthroplasty: a review. J Knee Surg. 2014; 27(3):193-7. 2. Moon HK, Han CD, Yang IH, Cha BS. Factors affecting outcome after total knee arthroplasty in patients with diabetes mellitus. Yonsei Med J. 2008; 49(1):129-37. 3. Santaguida PL, Hawker GA, Hudak PL, Glazier R, Mahomed NN, Kreder HJ, et al. Patient characteristics affecting the prognosis of total hip and knee joint arthroplasty: a systematic review. Can J Surg. 2008; 51(6):428-36. 4. Stan G, Orban H, Gruionu L, Gheorghe P. Coronal malposition effects in total knee arthroplasty: a finite element analysis. Eur J Orthop Surg Traumatol. 2013; 23(6):685-90. 5. Rienmüller A, Guggi T, Gruber G, Preiss S, Drobny T. The effect of femoral component rotation on the fiveyear outcome of cemented mobile bearing total knee arthroplasty. Int Orthop. 2012; 36(10):2067-72. 6. Liau JJ, Cheng CK, Huang CH, Lo WH. The effect of malalignment on stresses in polyethylene component of total knee prostheses--a finite element analysis. Clin Biomech (Bristol, Avon). 2002; 17(2):140-6. 7. O’Rourke MR, Callaghan JJ, Goetz DD, Sullivan PM, Johnston RC. Osteolysis associated with a cemented modular posterior-cruciate-substituting total knee design. J Bone Joint Surg Am. 2002; 84(8):1362-71. 8. Piazza SJ, Delp SL, Stulberg SD, Stern SH. Posterior tilting of the tibial component decreases femoral rollback in posterior-substituting knee replacement: a computer simulation study. J Orthop Res. 1998; 16(2):264-70. 9. Puloski SK, McCalden RW, MacDonald SJ, Rorabeck CH, Bourne RB. Tibial post wear in posterior stabilized total knee arthroplasty. An unrecognized source of polyethylene debris. J Bone Joint Surg Am. 2001; 83- A(3):390-7. 10. Yehyawi TM, Callaghan JJ, Pedersen DR, O’Rourke MR, Liu SS. Variances in sagittal femoral shaft bowing in patients undergoing TKA. Clin Orthop Relat Res. 2007; 464(1):99–104. 11. Lesh ML, Schneider DJ, Deol G, Davis B, Jacobs CR, Pellegrini VD Jr. The consequences of anterior femoral notching in total knee arthroplasty. A biomechanical study. J Bone Joint Surg Am. 2000; 82-A(8):1096-101. 12. Ritter MA, Thong AE, Keating EM, Faris PM, Meding JB, Berend ME, et al. The effect of femoral notching during total knee arthroplasty on the prevalence of postoperative femoral fractures and on clinical outcome. J Bone Joint Surg Am. 2005; 87(11):2411-4. 13. Shawen SB, Belmont PJ Jr, Klemme WR, Topoleski LD, Xenos JS, Orchowski JR. Osteoporosis and anterior femoral notching in periprosthetic supracondylar femoral fractures: a biomechanical analysis. J Bone Joint Surg Am. 2003; 85-A(1):115-21. 14. Tang WM, Chiu KY, Kwan MF, Ng TP, Yau WP. Sagittal bowing of the distal femur in Chinese patients who require total knee arthroplasty. J Orthop Res. 2005; 23(1):41–5. 15. Chung BJ, Kang YG, Chang CB, Kim SJ, Kim TK. Differences between sagittal femoral mechanical and distal reference axes should be considered in navigated TKA. Clin Orthop Relat Res. 2009; 467(9):2403-13. 16. Seo JG, Kim BK, Moon YW, Kim JH, Yoon BH, Ahn TK, et al. Bony landmarks for determining the mechanical axis of the femur in the sagittal plane during total knee arthroplasty. Clin Orthop Surg. 2009; 1(3):128-31. 17. McCormack D. Mechanical axis deviation: definitions, measurements and consequences. Irish J Orthopaed Surg. 2004; 2(1):1-9. 18. Kim YH, Park JW, Kim JS, Park SD. The relationship between the survival of total knee arthroplasty and postoperative coronal, sagittal and rotational alignment of knee prosthesis. Int Orthop. 2014; 38(2):379-85. 19. Lu ZH, Yu JK, Chen LX, Gong X, Wang YJ, Leung KK. Computed tomographic measurement of gender differences in bowing of the sagittal femoral shaft in persons older than 50 years. J Arthroplasty. 2012; 27(6):1216-20. 20. Nagamine R, Miura H, Bravo CV, Urabe K, Matsuda S, Miyanishi K, et al. Anatomic variations should be considered in total knee arthroplasty. J Orthop Sci. 2000; 5(3):232-7. 21. Harvey WF, Niu J, Zhang Y, McCree PI, Felson DT, Nevitt M, et al. Knee alignment differences between Chinese and Caucasian subjects without osteoarthritis. Ann Rheum Dis. 2008; 67(11):1524-8. 22. Cooke TD, Harrison L, Khan B, Scudamore A, Chaudhary MA. Analysis of limb alignment in the pathogenesis of osteoarthritis: a comparison of Saudi Arabian and Canadian cases. Rheumatol Int. 2002; 22(4):160-4. | ||
|
آمار تعداد مشاهده مقاله: 1,462 تعداد دریافت فایل اصل مقاله: 1,384 |
||
