Treatment of Displaced Sacroiliac Fracture Using the Lateral Window for Short Plate Buttress Reduction and Percutaneous Sacroiliac Screw Fixation. | ||
The Archives of Bone and Joint Surgery | ||
مقاله 16، دوره 4، شماره 2، تیر 2016، صفحه 173-176 اصل مقاله (1.95 M) | ||
نوع مقاله: TECHNICAL NOTE | ||
شناسه دیجیتال (DOI): 10.22038/abjs.2016.6264 | ||
نویسندگان | ||
Colin Murphy* ؛ James Gill؛ Andrew Carrothers؛ Peter Hull | ||
Department of Trauma & Orthopaedics, Addenbrooke’s Cambridge University Hospital, Cambridge, UK | ||
چکیده | ||
Fractures through the sacroiliac joint are very challenging to treat, technically difficult to reduce through closed methods on account of the multiaxial displacement of fractures fragments, frequently occur in very unwell patients, and have poor outcomes if malreduction is present. We describe a technique utilising the lateral window and a short buttress plate to reduce and stabilize the fragments prior to percutaneous fixation with sacroiliac screws. | ||
کلیدواژهها | ||
Fracture؛ Pelvic Trauma؛ Sacrum | ||
مراجع | ||
| ||
آمار تعداد مشاهده مقاله: 2,044 تعداد دریافت فایل اصل مقاله: 2,756 |