Modular Well-Fixed Hip Revision Stem Fracture: A Case Report and Literature Review | ||
The Archives of Bone and Joint Surgery | ||
مقاله 10، دوره 12، شماره 10، دی 2024، صفحه 735-741 اصل مقاله (1.07 M) | ||
نوع مقاله: CASE REPORT | ||
شناسه دیجیتال (DOI): 10.22038/abjs.2024.80313.3666 | ||
نویسندگان | ||
Fabio Pessina1؛ Carlo Cazzaniga2؛ Beatrice Manzini2؛ Carlo Cardile* 2 | ||
1Department of Medicine and Surgery, University of Milano-Bicocca, Monza, Italy | ||
2Department of Orthopedics and Trauma Surgery, ASST Rhodense, Ospedale Salvini, Garbagnate Milanese, Milano, Italy | ||
چکیده | ||
This study presents a case of repeated prosthetic fracture in a modular hip prosthesis in a 56-year-old male patient.After the initial implantation of a modular total hip prosthesis in 2006, the patient experienced two instances of prosthetic implant fracture over seventeen years. In this study, we analyz e the clinical case, explore potential underlying causes of this complication, and delve into current indications and strategies for the revision of fractured prosthesis stems. The discussion is informed by a literature review and underscores the significance of selecting appropriate revision techniques to address this challenge. Level of evidence: III | ||
کلیدواژهها | ||
Fracture؛ Hip arthroplasty؛ Modular؛ Revision؛ Well-fixed stem | ||
مراجع | ||
1. Gautam D, Malhotra R. Total Hip Arthroplasty with Modular Stem for Dysplastic Hips in South Asian Population. Arch Bone Jt Surg. 2019; 7(6):506-513. 2. Solarino G, Vicenti G, Carrozzo M, Ottaviani G, Moretti B, Zagra L. Modular neck stems in total hip arthroplasty: current concepts. EFORT Open Rev. 2021; 6(9):751-758. doi: 10.1302/2058-5241.6.200064. 3. Pelayo-de-Tomás JM, Rodrigo-Pérez JL, Novoa-Parra CD, Lizaur-Utrilla A, Morales-Suárez-Varela M, Blas-Dobón JA. Cementless modular neck stems: are they a safe option in primary total hip arthroplasty? Eur J Orthop Surg Traumatol. 2018; 28(3):463-469. doi: 10.1007/s00590-017-2071-0. 4. Morlock MM, Hube R, Wassilew G, Prange F, Huber G, Perka C. Taper corrosion: a complication of total hip arthroplasty. EFORT Open Rev. 2020; 5(11):776-784. doi: 10.1302/2058- 5241.5.200013. 5. Graves SE, de Steiger R, Davidson D, et al. The use of femoral stems with exchangeable necks in primary total hip arthroplasty increases the rate of revision. Bone Joint J. 2017; 99-B (6):766-773. doi: 10.1302/0301-620X.99B6.38020. 6. Mohan R, Unnikrishnan N, Gudena R. Cantilever Failure of Modular Uncemented Femoral Revision Stem in Patients with Poor Proximal Femoral Support; How to avoid it? Arch Bone Jt Surg. 2024; 12(4):240-244. doi: 10.22038/ABJS.2023.75373.3485. 7. Sivananthan S, Lim CT, Narkbunnam R, Sox-Harris A, Huddleston JI 3rd, Goodman SB. Revision Hip Arthroplasty Using a Modular, Cementless Femoral Stem: IntermediateTerm Follow-Up. J Arthroplasty. 2017; 32(4):1245-1249. doi: 10.1016/j.arth.2016.10.033. 8. Valtanen RS, Hwang KL, Amanatullah DF, Huddleston JI 3rd, Maloney WJ, Goodman SB. Revision Hip Arthroplasty Using a Modular, Cementless Femoral Stem: Long-Term Follow-Up. J Arthroplasty. 2023; 38(5):903-908. doi: 10.1016/j.arth.2022.12.018. 9. Skendzel JG, Blaha JD, Urquhart AG. Total hip arthroplasty modular neck failure. J Arthroplasty. 2011; 26(2):338.e1- 338.e3384. doi: 10.1016/j.arth.2010.03.011. 10. Wright G, Sporer S, Urban R, Jacobs J. Fracture of a modular femoral neck after total hip arthroplasty: a case report. J Bone Joint Surg Am. 2010; 92(6):1518-1521. doi: 10.2106/JBJS.I.01033. 11. Papaioannou I, Repantis T, Baikousis A, Korovessis P. Late Onset Disassembly of a Modular Neck-stem Component after Cementless Hip Replacement without Dislocation: A Case Report and Review of Literatures. Hip Pelvis. 2018; 30(3):190-195. doi: 10.5371/hp.2018.30.3.190. 12. Zajc J, Predan J, Gubeljak N, Moličnik A, Fokter SK. Modular femoral neck failure after revision of a total hip arthroplasty: a finite element analysis. Eur J Orthop Surg Traumatol. 2019; 29(3):717-723. doi: 10.1007/s00590-018-2314-8. 13. Kouzelis A, Georgiou CS, Megas P. Dissociation of modular total hip arthroplasty at the neck-stem interface without dislocation. J Orthop Traumatol. 2012; 13(4):221-224. doi: 10.1007/s10195-011-0172-9. 14. Gallart X, Claret G, Garcia S, Fernández-Valencia JA, Riba J. Rupture of Extensively Porous Coated Stems. - A Case Series of 2 Patients. J Orthop Case Rep. 2014; 4(3):36-39. doi: 10.13107/jocr.2250-0685.192. 15. Canton G, Barbo G, Roberto Fattori R, Nicholas Rasio N, Murena L. Total hip arthroplasty monobloc stem neck rupture in patient with massive heterotopic ossifications: a case report and literature review. Acta Biomed. 2023; 94(S2):e2023117. doi: 10.23750/abm.v94iS2.13888. 16. Akrawi H, Magra M, Shetty A, Ng A. A modified technique to extract fractured femoral stem in revision total hip arthroplasty: A report of two cases. Int J Surg Case Rep. 2014; 5(7):361-364. doi: 10.1016/j.ijscr.2014.04.003. 17. Graulich TJ, Graeff P, Heidenblut T, Krettek C, Liodakis E. Revision of a Fractured Titanium Modular Revision Hip Stem Without Removal of the Well-Fixed Part of the Stem: A New Approach Using a Cemented Tube. Arthroplast Today. 2020; 6(3):363-368. doi: 10.1016/j.artd.2020.04.018. 18. Pelayo-de-Tomás JM, Rodrigo-Pérez JL, Novoa-Parra CD, Lizaur-Utrilla A, Morales-Suárez-Varela M, Blas-Dobón JA. Cementless modular neck stems: are they a safe option in primary total hip arthroplasty? Eur J Orthop Surg Traumatol. 2018; 28(3):463-469. doi: 10.1007/s00590-017-2071-0. 19. Benazzo F, Rossi SM, Cecconi D, Piovani L, Ravasi F. Mid-term results of an uncemented femoral stem with modular neck options. Hip Int. 2010; 20(4):427-433. doi: 10.1177/112070001002000403. 20. Prudhon JL, Tardy N. Extended trochanteric osteotomy: comparison of 3 modes of fixation: metallic wires, cables, plate, about a series of 157 cases. SICOT J. 2018; 4:21. doi: 10.1051/sicotj/2018017. 21. Sundaram K, Siddiqi A, Kamath AF, Higuera-Rueda CA. Trochanteric osteotomy in revision total hip arthroplasty. EFORT Open Rev. 2020; 5(8):477-485. doi: 10.1302/2058- 5241.5.190063. 22. Mahmood S, Muffly BT, Bradbury TL. The "Inside-Out" Anterior Osteotomy of the Proximal Femur via the Direct Anterior Approach in Revision Hip Arthroplasty. Arthroplast Today. 2023; 24:101219. doi: 10.1016/j.artd.2023.101219. 23. Solou K, Panagopoulos A, Tatani I, Megas P. Fracture of femoral neck in modular total hip arthroplasty: a systematic review of the literature. Hip Int. 2024; 34(3):409-420. doi: 10.1177/11207000231211253. 24. Sukopp M, Taylor D, Forst R, Seehaus F. Femoral Stem Fracture in Hip Revision Arthroplasty: A Systematic Literature Review of the Real-World Evidence. Z Orthop Unfall. 2022; 160(2):160-171. doi: 10.1055/a-1348-2873. | ||
آمار تعداد مشاهده مقاله: 240 تعداد دریافت فایل اصل مقاله: 187 |