Investigation of Leakage and Transmission Radiation through the MLC Version I2 Applied To the Elekta Synergy 6 MV Photon Beam Linac | ||
Iranian Journal of Medical Physics | ||
مقاله 3، دوره 19، شماره 6، بهمن و اسفند 2022، صفحه 334-345 اصل مقاله (3.47 M) | ||
نوع مقاله: Original Paper | ||
شناسه دیجیتال (DOI): 10.22038/ijmp.2022.62432.2055 | ||
نویسندگان | ||
Deae-eddine KRIM* 1؛ Dikra Bakari2؛ Mustapha Zerfaoui3؛ abdeslem rrhioua4؛ Mohammed Hamal4؛ Khalid ELOUARDY4 | ||
1LPMR, Faculty of sciences, University Mohamed 1st, Oujda, Moroccco. | ||
2National School of Applied Sciences, University Mohamed 1st, Oujda, Morocco | ||
3LPMR, Faculty of sciences, University Mohamed 1st, Oujda, Morocco | ||
4LPMR, Faculty of sciences, University Mohamed 1st, Oujda, Morocco. | ||
چکیده | ||
Introduction: Radiotherapy and nuclear medicine extensively use Monte Carlo simulation to study particle transport and interactions. The aim of this task is the investigation and simulation of leakage and transmission (L&T) particles using the Multi-Leaf Collimator version i2 applied to the Elekta Synergy linac. Material and Methods: In this study, all linac segments are included in the simulation model. In order to reduce MC calculation time, the new HPC-Slurm cluster platform and the Python phase space approach are used. To study the transmission between MLCi2 leaves, a detailed analysis of the dose distribution was conducted. Results: The simulation results obtained with Gate 9.0 MC are excellently correlated with the measured data with error estimates for the 6 MV photon beam parameters less than 1% and a validation level of 99% in terms of the gamma index's (2%/2mm) threshold formalism for the cross profiles and PDD's dose distributions. The results indicate that contamination particles (e-, e+) have an effect on the distribution of dose in the patient. These particles are present in the beam produced previously and which is assumed to contain only X-rays. In addition, a three-dimensional distribution of dose inside the tumor (CT-scan) confirms the L&T effect of the studied version of the multi leaf collimator (MLCi2), with a dose range of around 70% of the delivered dose to the tumor, resulting in secondary outcomes at the DNA. Conclusion: Consequently, the production of a new generation of MLC that can limit this L&T effect should be encouraged. | ||
کلیدواژهها | ||
Radiotherapy Monte Carlo Multi؛ Leaf Collimator Mlci2 Leakage and Transmission L&T | ||
مراجع | ||
| ||
آمار تعداد مشاهده مقاله: 484 تعداد دریافت فایل اصل مقاله: 310 |