Distal Femoral Valgus Cut Errors in Total Knee Replacement | ||
| The Archives of Bone and Joint Surgery | ||
| دوره 8، شماره 3، مرداد 2020، صفحه 463-464 اصل مقاله (235.48 K) | ||
| نوع مقاله: LETTER TO THE EDITOR | ||
| شناسه دیجیتال (DOI): 10.22038/abjs.2020.46578.2280 | ||
| نویسندگان | ||
| Hamidreza Yazdi1؛ Mohammad Taher Ghaderi* 2 | ||
| 1Bone and Joint Reconstruction Research Centre, Firoozgar Hospital, Department of Knee Surgery, Iran Univesity of Medical Sciences, Tehran, Iran | ||
| 2Bone and Joint Reconstruction Research Center, Shafa Orthopedic Hospital, Iran University of Medical Sciences, Tehran, Iran | ||
| چکیده | ||
| The causes of malalignment in total knee arthroplasty can be categorized into three different groups; 1) Errors in bone cuts 2) Errors in implant fixations, and 3) The method of setting down the cutting guides (1). We would like to announce that more several distal femoral valgus cut errors may occur during total knee replacement. | ||
| کلیدواژهها | ||
| valgus dut؛ distal femoral cut؛ cut error؛ total knee replacement | ||
| مراجع | ||
|
1. Lampart M, Behrend H, Moser LB, Hirschmann MT. Due to great variability fixed HKS angle for alignment of the distal cut leads to a significant error in coronal TKA orientation. Knee Surgery, Sports Traumatology, Arthroscopy. 2019; 27(5):1434-41. 2. Dorr LD, editor. The knee: papers of the First Scientific Meeting of the Knee Society. Univ Park Pr; 1985. 3. Jeffery RS, Morris RW, Denham RA. Coronal alignment after total knee replacement. The Journal of bone and joint surgery. British volume. 1991; 73(5):709-14. 4. Kim TK, Chang CB, Kang YG, Chung BJ, Cho HJ, Seong SC. Execution accuracy of bone resection and implant fixation in computer assisted minimally invasive total knee arthroplasty. The Knee. 2010; 17(1):23-8. 5. Moreland JR. Mechanisms of failure in total knee arthroplasty. Clinical orthopaedics and related research. 1988 (226):49-64. 6. Ritter MA, Faris PM, Keating EM, Meding JB. Postoperative alignment of total knee replacement. Its effect on survival. Clinical orthopaedics and related research. 1994 (299):153-6. 7. Mont MA, Urquhart MA, Hungerford DS, Krackow KA. Intramedullary goniometer can improve alignment in knee arthroplasty surgery. The Journal of arthroplasty. 1997; 12(3):332-6. 8. Nakahara H, Matsuda S, Moro-oka TA, Okazaki K, Tashiro Y, Iwamoto Y. Cutting error of the distal femur in total knee arthroplasty by use of a navigation system. The Journal of arthroplasty. 2012; 27(6):1119-22. 9. Reed SC, Gollish J. The accuracy of femoral intramedullary guides in total knee arthroplasty. The Journal of arthroplasty. 1997; 12(6):677-82. 10. Otani T, Whiteside LA, White SE. Cutting errors in preparation of femoral components in total knee arthroplasty. The Journal of arthroplasty. 1993; 8(5):503-10. 11. Plaskos C, Hodgson AJ, Inkpen K, McGraw RW. Bone cutting errors in total knee arthroplasty. The Journal of arthroplasty. 2002; 17(6):698-705. 12. Yazdi H, Nazarian A, Wu JS, Amiri A, Hafezi P, Babikian M, et al. Different references for valgus cut angle in Total Knee Arthroplasty. Archives of Bone and Joint Surgery. 2018; 6(4):289. | ||
|
آمار تعداد مشاهده مقاله: 712 تعداد دریافت فایل اصل مقاله: 418 |
||