Determination of Diagnostic Reference Level in routine Computed radiography examination in north of Iran | ||
| Iranian Journal of Medical Physics | ||
| مقاله 265، دوره 15، Special Issue-12th. Iranian Congress of Medical Physics، بهمن و اسفند 2018، صفحه 267-267 | ||
| نوع مقاله: Conference Proceedings | ||
| شناسه دیجیتال (DOI): 10.22038/ijmp.2018.12911 | ||
| نویسندگان | ||
| Roya Bordbar1؛ Ali shabestani Monfared2؛ Mohammad Reza Deevband3؛ Fatemeh Niksirat4؛ Kourosh Ebrahimnejad Gorji5 | ||
| 1Msc Student of Medical Physics Radiobiology and Radiation Protection Department, Faculty of Medicine, Babol University of Medical Sciences, Babol, Iran | ||
| 2Professor of Medical Physics, Department of Medical Physics Radiobiology and Radiation Protection, Faculty of Medicine, Babol University of Medical Sciences, Babol, Iran | ||
| 3PHD of Medical Physics, Department of Medical Physics and Engineering, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran | ||
| 4MSc of Medical Physics Radiobiology and Radiation Protection Department, Faculty of Medicine, Babol University of Medical Sciences, Babol, Iran | ||
| 5PHD of Medical Physics, Department of Medical Physics Radiobiology and Radiation Protection, Faculty of Medicine, Babol University of Medical Sciences, Babol, Iran | ||
| چکیده | ||
| Introduction: Digital radiography has a major role in nowadays healthcare system so radiation protection (justification and optimization) is important in this field. Many related organizations to protection suggested to establish national and regional diagnostic reference level for medical procedures. Reference levels are typically set at the 75th percentile of the dose distribution from a survey conducted across a broad user base using a special dose measurement protocol and phantom. This study aimed to establish diagnostic reference level for computed radiography examination in north of Iran. Materials and Methods: The data were collected from 7 public hospitals for 12 computed radiographies routine examination including: skull (AP-LAT), cervical (AP-LAT), chest (PA –LAT), thoracic (AP- LAT), lumbar(AP-LAT), abdomen(AP) and pelvis (AP). For each projection, 10 patients at least 18 years olds were investigated. The study was performed by filling out the questioner which was contained the following parameters: Center name, machine manufacturer, Type of Examination, Tube Voltage (kVp), Current Time Product (mAs) and Film Focus Distance (FFD). The quantity of entrance skin dose is evaluated by measuring ESD. The third quartile of ESD related to each projection was considered as DRL of that examination. Results: Based on the data of this study, we expected that diagnostic reference level of computed radiography examination in north of Iran is in accordance with standard values that were suggested by regulatory organizations such as American College of Radiology (ACR)and European Commission (EC). Conclusion: The comparison of the results of this survey with surveys performed in other countries will indicate the protection level of patients in computed radiography examination in north of Iran. | ||
| کلیدواژهها | ||
| Computed Radiography؛ Reference Values؛ Dosimetry؛ Population Exposure | ||
|